

#ABBOTT ISTAT MENUS SKIN#
Capillary tubes and direct skin punctures (e.g.When drawn into an evacuated tube containing EDTA, samples should not be used unless the blood collection tube is filled at least half full.The use of whole blood or plasma samples containing other anticoagulants such as oxalate and citrate is not reccommended.BNP cartridges require the use of EDTA whole blood or plasma samples collected in plastic syringes or evacuated tubes containing EDTA.Samples should not be used unless the blood collection tube is filled at least half full.fingersticks) should not be used with the cTnI or CK-MB cartridge. The use of whole blood or plasma samples containing other anticoagulants such as EDTA, oxalate, and citrate will cause deactivation of the alkaline phosphatase, resulting in decreased cTnI or CK-MB readings.non-heparinized whole blood or plasma samples tested within one minute of drawing from a patient into a plastic syringe or plastic evacuated tube containing no additives. heparinized whole blood or plasma samples collected in syringes or evacuated tubes containing lithium or sodium heparin, orī. cTnI and CK-MB cartridges require the use of either:Ī. Abbott Point-of-Care) has 26 waived tests across 11 panels, including the only waived comprehensive metabolic panel (Figure 3-70).heparinized whole blood collected in evacuated tubes containing lithium or sodium heparin, as long as the tubes are filled to capacity. heparinized whole blood collected in balanced heparin syringes or capillary tubes, orĬ. whole blood collected in non-heparinized capillary tubes, evacuated tubes, or syringes, as long as sample is tested immediately upon draw,ī. For skin puncture testing for PT/INR, see the section on "Patient Test Procedures".Ī.Withdraw the sample into a fresh plastic syringe with no anticoagulant, and test immediately. Flush the extracorporeal blood access line by withdrawing 5 mL of blood into a syringe and discard the syringe.ī. For extracorporeal line testing for ACT:Ī.Withdraw 2 mL of blood into a syringe and discard it.Ĭ. Fluid drip through the line must be discontinued.ī. If a second measurement is needed, draw a fresh sample.Ī.For venipuncture, some experts recommend drawing and discardingĪ sample of at least 1 mL prior to drawing samples for coagulation testing.Use plain plastic syringes or plastic evacuated tubes with no anticoagulant, activators, or serum separators.The ACT test can be performed using venous or arterial samples, while the PT/INR test can be performed using capillary or venous samples.Do not “milk” finger or heel while collecting sample.Allow alcohol to dry over puncture site before collecting sample.For all analytes including ionized calcium, use plain or balanced heparin capillary tubes. Skin puncture: Lithium heparin capillary tubes for testing all analytes but ionized calcium. Do not leave tourniquet on for more than 2 minutes. Venous: Collection tube with lithium or sodium heparin filled to capacity and mixed by gentle inversion at least 10 times. If not tested immediately, remix and discard 2 drops of blood before filling cartridge.Avoid drawing air into syringes for blood gas and ionized calcium tests.Test for other analytes within 30 minutes. Samples for pH, PCO 2, PO 2, TCO 2 and ionized calcium should be tested within 10 minutes. Mix heparinized syringes by rolling between palms for at leastĥ seconds in 2 directions, then invert the syringe repeatedly for at least 5 For ionized calcium, use balanced heparin syringes. The benefits of i-STAT 1 Wireless, seamlessly integrated with your wireless network:Įasy to integrate with Electronic Medical RecordsĮmploy real-time sharing of test results with broad clinical teams and caregiversĪllows clinicians to make informed decisions from bedside or anywhere EMR is availableĮnables mobile, real-time result transmission" Arterial: Plain syringe, heparinized syringe labeled for analytes to be tested and filled to capacity, or syringe with minimum volume of heparin to prevent clotting (10 U/mL of blood). THE I-STAT SYSTEM RANGE OF DIAGNOSTICS TESTS The i-STAT 1 Wireless allows medical staff to quickly perform patient-side tests and upload results to the Electronic Medical Record (EMR) and Lab Information System (LIS) to enable rapid treatment decisions, optimizing patient care.
#ABBOTT ISTAT MENUS PORTABLE#
The i-STAT 1 Wireless portable blood analyzer combines all the features of the i STAT 1 analyzer with the convenience of wireless transmission for even greater efficiency.
